PMC-D/PMC-D20 Drive Control Unit

The intrinsically safe Cat® PMC-D control is used on shearer or plow faces to provide high level AFC (armed face conveyor) and plow automation. Each Drive unit needs to be equipped with one PMC-D control unit and equivalent I/O to operate the CST drives or UEL gearbox functions. In such a system a Cat PMC-V provides the Human Machine Interface (HMI) to interfere with the PMC-D controls to operate manual mode, visualize and change parameters and show actual process values. Within a PMC-D system minimum one and typically up to 3 PMC-Vs are in equal operation. The PMC-D system can control extremely sensitive the speed and torque of highly powered AFC CST drive. Using Profibus network all PMC-Ds and PMC-Vs in a system could exchange process data over long distances with high frequency.

Specifications
Product Brochures
Units: US Metric
Components
Operating System
µITRON RTOS
Processor
32Bit RISC Microcontroller TX1940CYAF, 32MHz, internal RAM 10Kbytes, ROM 256Kbytes
RAM Memory
4Mbytes CMOS Static RAM, 4Mbytes Flash
Global Certifications
Types (3)
More certifications on demand
Types (6)
Russia: GOST
Types (1)
Europe: ATEX
Types (4)
Australia: IECEx, ANZEx
Types (5)
China: MA
Types (2)
U.S.: MSHA
Electrical Data
Supply Current - Maximum Ratings
1.5 A
1.5 A
Supply Current - Typical Value
1 A
1 A
Supply Voltage - Typical Value
12 V DC
Supply Voltage - Maximum Ratings
9.5 V - 13.2 V
Environmental Data
Temperature - Typical Value
68 °F
20 °C
Temperature - Symbol
Tamb
Temperature - Maximum Ratings
-20° C - +40° C (-4° F - +104° F)
Electrical Sockets
Socket 3 - Pin 3
Serial Interface: TxD_B
Socket 4 - Pin 2
Serial Interface: RxD_C
Socket 1 - Pin 1
Optocoupler Anode
Socket 15 - Pin 4
CM-GND
Socket 17 - Pin 3
CM-Sensor -
Socket 13 - Pin 2
CM-Sensor +
Socket 18 - Pin 2
CM-Sensor +
Socket 14 - Pin 4
CM-GND
Socket 12 - Pin 3
TP b
Socket 8 - Pin 1
Multi Mode Input 4
Socket 4 - Pin 3
Serial Interface: TxD_C
Socket 3 - Pin 4
GND
Socket 10 - Pin 2
Multi Mode Input 3
Socket 10 - Pin 3
+8.2 V (output)
Socket 20 - Pin 2
CM-Sensor +
Socket 11 - Pin 1
+12 V (output)
Socket 20 - Pin 4
CM-GND
Socket 15 - Pin 2
CM-Sensor +
Socket 4 - Pin 4
GND
Socket 13 - Pin 3
CM-Sensor -
Socket 8 - Pin 4
GND
Socket 3 - Pin 2
Serial Interface: RxD_B
Socket 19 - Pin 4
CM-GND
Socket 11 - Pin 4
GND
Socket 2 - Pin 3
Serial Interface: TxD_0
Socket 13 - Pin 4
CM-GND
Socket 5 - Pin 1
+12 V (C) (output)
Socket 19 - Pin 2
CM-Sensor +
Socket 14 - Pin 3
CM-Sensor -
Socket 19 - Pin 3
CM-Sensor -
Socket 14 - Pin 2
CM-Sensor +
Socket 17 - Pin 4
CM-GND
Socket 7 - Pin 4
GND (Power Supply)
Socket 8 - Pin 3
+8.2 V (output)
Socket 10 - Pin 1
+12 V (output)
Socket 7 - Pin 1
+12 V (Power Supply)
Socket 5 - Pin 4
GND
Socket 6 - Pin 3
Profibus: b (internal)
Socket 16 - Pin 2
CM-Sensor +
Socket 11 - Pin 2
Multi Mode Input 6
Socket 12 - Pin 2
TP a
Socket 2 - Pin 2
Serial Interface: RxD_0
Socket 16 - Pin 3
CM-Sensor -
Socket 20 - Pin 3
CM-Sensor -
Socket 1 - Pin 2
Relay Contact NO: a
Socket 18 - Pin 4
CM-GND
Socket 2 - Pin 1
+12 V (A) (output)
Socket 16 - Pin 4
CM-GND
Socket 1 - Pin 4
Optocoupler Cathode
Socket 9 - Pin 4
GND
Socket 9 - Pin 1
Multi Mode Input 5
Socket 9 - Pin 2
Multi Mode Input 2
Socket 11 - Pin 3
+8.2 V (output)
Socket 10 - Pin 4
GND
Socket 3 - Pin 1
+12 V (B) (output)
Socket 8 - Pin 2
Multi Mode Input 1
Socket 5 - Pin 3
Switch 2
Socket 9 - Pin 3
+8.2 V (output)
Socket 5 - Pin 2
Switch 1
Socket 4 - Pin 1
+12 V (C) (output)
Socket 18 - Pin 3
CM-Sensor -
Socket 1 - Pin 3
Relay Contact NO: b
Socket 17 - Pin 2
CM-Sensor +
Socket 2 - Pin 4
GND
Socket 15 - Pin 3
CM-Sensor -
Socket 6 - Pin 2
Profibus: a (internal)
HEALTH for Longwall Vibration Analysis
Provides vibration monitoring functionality for longterm health monitoring of the following longwall related equipment: (3)
• Stage loader gearbox and relating motor • Crusher and relating motor
Provides vibration monitoring functionality for longterm health monitoring of the following longwall related equipment: (2)
• Shearer haulage and ranging arm gearboxes • Water/HFA pump station
Provides vibration monitoring functionality for longterm health monitoring of the following longwall related equipment: (1)
• CST gearbox and relating motor • UEL gearbox and relating motor
PMC-D Dimensions and Plug Assignments - Approximate
Length
13.19 in
335 mm
Width
10.94 in
278 mm
Height
5.83 in
148 mm
PMC-D20 Dimensions and Plug Assignments - Approximate
Length
13.19 in
335 mm
Width
10.98 in
279 mm
Height
4.92 in
125 mm